Windows Time Client.


3.4.8 Clear Procedure

Previous  Top  Next

The clear procedure is called when some event occurs that results in a significant change in reachability state or potential disruption of the local clock.

 

begin clear procedure

       peer.org <-- 0 (undefined);                                  /* mark timestamps undefined */

       peer.rec <-- 0 (undefined);

       peer.xmt <-- 0 (undefined);

       peer.reach <-- 0;                                            /* reset state variables */

       peer.filter <-- [0, ,0,NTP.MAXDISPERSE];          /* all stages */

       peer.valid <-- 0;

       peer.dispersion <-- NTP.MAXDISPERSE;

       peer.hostpoll <-- NTP.MINPOLL;                     /* reset poll interval */

       call poll-update;

       call clock-select;                                             /* select clock source */

end clear procedure;

 


Bytefusion Software Prices Site Map Purchase This Product On-line